Solar Off Grid PWM PCU
KEY FEATURES
- Wave Type: Pure Sine Wave
- Charger Technology: Pulse with modulation
- Solar panel current: 50 amps
- Solar panel VOC: 45-50V
- Transfer Time: ≤ 12 msec.
- Mains Re-Connect / Dis-Connect Voltage: 23 V & 28.2 V
- Protections: Short Circuit, High voltage, Low battery shutdown
- Pure Sine Wave Technology using PWM topology with inbuilt Real Time Clock.
- Smart solar selection for max. utilization of Solar Power.
800×360×295
Description
PWM Based Charge Controller
Switching Element
MOSFET
Controller
Digital Signal Processor dsPIC
Efficiency
95%
Solar Working Mode Selection by Dip Switch
SMART/HYBRID/PCU
Battery
Low Cut Off Recovery by (SPV Charging)
11.5V (Per Battery) +/- 2%
Low Buzzer
10.7V (Per Battery) +/- 2%
High Cut Off Recovery
15.5V / 15.0V (Per Battery) +/- 2%
Boost Charging Voltage by SPV
14.8V (Per Battery) +/- 2%
Boost Charging Voltage by Grid
14.4V+/- 2%
Float Charging Volt by Grid
13.8VBattery +/- 2%
Output (Inverter)
Output @ No Load
230V +/- 2% 1 Phase 3 Wire P,N,E
Output Frequency
50 Hz +/- 2%
Output Low/Shortcircuit Retry
1 Time
No Load Current (NLC)
2%
Display Parameters
Display
16X2 Display (20X4 LCD Alphanumeric (5KVA)
Inverter Display
Voltage, Load % and Frequency
Solar Display
Voltage, Current, Power
Mains Grid Display
Voltage and Frequency
Battery Display
Voltage and Charging Current
Status / Fault Display
Inverter Status, Mains Status, Charger Status, Battery Status, Charging Status, Solar Status, Solar Charger Status
Inverter
Switching Element
MOSFET
Output Waveform
Digital Filtered Pure Sine Wave
Overload Retry
3 Times
Switch
System On/Off, Hybrid / Smart Switch, Inverter / UPS Mode Switch
Indication
UPS, Mains, Charging (Solar & Mains), Battery, Overload
Alarm
Inverter On/Off, Mains Charger On, Solar Charger On, Overload, Battery Low
Protection
Overload, Short circuit, Over voltage, Under Voltage, Mains Surge and Transient by MOV and Varistors, Reverse Polarity of Battery, Over Temperature, Solar Reverse, SPV Surge
Cooling
Forced Air Cooling (Temperature Controlled)
Operating Temperature
0-50 Degree Celsius
INVERTER SWITCH
Push to On and push to Off switch. Whenever this switch is On, the Inverter will automatically turn on, until any unavoidable fault occurs. If the fault is recovered in case of static bypass, the inverter will automatically switch on.
20X4 ALPHANUMERIC DISPLAY
Big display to show all parameters related to Inverter, Battery and Mains. Also, display the system internal parameters and status. It helps the electrician and service engineer to easily diagnose the problem.
CONFIGURATION SWITCHES
UP, DOWN, SELECT, BACK switches are used to navigate into the menu, for various settings related to the system.
LED INDICATION
5 LEDs, UPS, Charging, Mains, Battery, Overload are given to easily identify the state of the system and diagnose the fault.
INVERTER SWITCH
Push to On and push to Off switch. Whenever this switch is On, the Inverter will automatically turn on, until any unavoidable fault occurs. If the fault is recovered in case of static bypass, the inverter will automatically switch on.
20X4 ALPHANUMERIC DISPLAY
Big display to show all parameters related to Inverter, Battery and Mains. Also, display the system internal parameters and status. It helps the electrician and service engineer to easily diagnose the problem.
CONFIGURATION SWITCHES
UP, DOWN, SELECT, BACK switches are used to navigate into the menu, for various settings related to the system.
LED INDICATION
5 LEDs, UPS, Charging, Mains, Battery, Overload are given to easily identify the state of the system and diagnose the fault.
How it works?
Electrower’s Solar Off-Grid PWM PCU consists of a PWM Solar Charge Controller, Offline Inverter, and a Grid Charger all in an integrated form. The Off-Grid Solar PCU is designed to maximise the use of Solar Power. When the batteries are charged from Solar, the Smart PCU disconnects Grid/Mains/DG and let the Inverter/Load run on Solar. It let user enhance use of solar power, also as per the user preferences it has twpmodes:
- Smart Mode (PCU gives priority to solar, second priority to the grid and third priority to the batteries in smart mode). Recommended in Semi-Urban Area, where power cut is less than 2 hours.
- Hybrid Mode (In this mode PCU works well with solar as well as batteries. Grid charging only takes place when solar power is not sufficient to charge the batteries). Recommended in Rural Area, where power cut is more than 2-3 hours.
Technical Specification
MODELS / RATINGS